{"id":22992,"date":"2024-02-15T08:34:26","date_gmt":"2024-02-15T08:21:01","guid":{"rendered":"https:\/\/krohne-inor.staging.rackfish.net\/?post_type=product&#038;p=22992"},"modified":"2025-03-13T09:55:24","modified_gmt":"2025-03-13T09:55:24","slug":"sr361","status":"publish","type":"product","link":"https:\/\/krohne-inor.staging.rackfish.net\/en\/product\/sr361\/","title":{"rendered":"SR361"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text el_id=&#8221;tech-specifications&#8221; el_class=&#8221;tech section&#8221;]<\/p>\n<h2>Technical Specification<\/h2>\n<table>\n<tbody>\n<tr>\n<td><strong>Input Current<\/strong><\/td>\n<td>0(4) to 20 mA<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td>5 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Maximum overload<\/td>\n<td>200 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Input Voltage<\/strong><\/td>\n<td>0(2) to 10 V<\/td>\n<\/tr>\n<tr>\n<td>Input impedance<\/td>\n<td>120 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Maximum overload<\/td>\n<td>300 V<\/td>\n<\/tr>\n<tr>\n<td>2-wire Transmitter Supply +Us<\/td>\n<td>16 V at UPower = 24 V, (13 &#8230; 22 V depending on the supply voltage) current limited \u2264\u00a030 mA<\/td>\n<\/tr>\n<tr>\n<td><strong>Output, Relay 1 &amp; 2<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Relay contacts<\/td>\n<td>1-pole switch over contact (SPDT)<\/td>\n<\/tr>\n<tr>\n<td>Contact rating max.<\/td>\n<td>AC: 250 V \/ 6 A, 1500 VA<br \/>\nDC: 250 V \/ 0.2 A, 115 V \/ 0.3 A, 30 V \/ 6 A<\/td>\n<\/tr>\n<tr>\n<td>Relay function<\/td>\n<td>Monostable, Normally active or passive (switch selectable)<\/td>\n<\/tr>\n<tr>\n<td>Alarm functions, relay 1 &amp; 2<\/td>\n<td>High\/Low alarm (switch selectable)<\/td>\n<\/tr>\n<tr>\n<td>Alarm indication<\/td>\n<td>Alarm state indicated by yellow LED<\/td>\n<\/tr>\n<tr>\n<td>Response time<\/td>\n<td>approx. ca. 20 ms<\/td>\n<\/tr>\n<tr>\n<td><strong>Operation temperature<\/strong><\/td>\n<td>-20 to +60 \u00b0C \/ -4 to +140 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td><strong>Galvanic isolation<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Input \/ power supply \/ relay outputs<\/td>\n<td>4 kVAC, 1 min<\/td>\n<\/tr>\n<tr>\n<td>Relay 1 \/ Relay 2<\/td>\n<td>3 kVAC, 1 min<\/td>\n<\/tr>\n<tr>\n<td><strong>Power supply<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Voltage<\/td>\n<td>24 VAC\/DC \u00b115 %, 48 to 62 Hz (AC supply). 24 V CD, \u00b1 15 %, 1.0 W<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical accuracy<\/strong><\/td>\n<td>Trip point: \u00b10.2 % of span<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting<\/strong><\/td>\n<td>35 mm DIN rail acc. to EN 60715<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_column_text el_id=&#8221;documents&#8221; el_class=&#8221;docs section&#8221;]<\/p>\n<h2>Documents<\/h2>\n<p>[wpfd_category id=&#8217;12162&#8217;\/][\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text el_id=&#8221;tech-specifications&#8221; el_class=&#8221;tech section&#8221;]<br \/>\nTechnical Specification<\/p>\n<p>Input Current<br \/>\n0(4) to 20 mA<\/p>\n<p>Input impedance<br \/>\n5 \u03a9<\/p>\n<p>Maximum overload<br \/>\n200 mA<\/p>\n<p>Input Voltage<br \/>\n0(2) to 10 V<\/p>\n<p>Input impedance<br \/>\n120 k\u03a9<\/p>\n<p>Maximum overload<br \/>\n300 V<\/p>\n<p>2-wire Transmitter Supply +Us<br \/>\n16 V at UPower = 24 V, (13 &#8230; 22 V depending on the supply voltage) current limited \u2264\u00a030 mA<\/p>\n<p>Output, Relay 1 &amp; 2<\/p>\n<p>Relay contacts<br \/>\n1-pole switch over contact (SPDT)<\/p>\n<p>Contact rating max.<br \/>\nAC: 250 V \/ 6 A, 1500 VA<br \/>\nDC: 250 V \/ 0.2 A, 115 V \/ 0.3 A, 30 V \/ 6 A<\/p>\n<p>Relay function<br \/>\nMonostable, Normally active or passive (switch selectable)<\/p>\n<p>Alarm functions, relay 1 &amp; 2<br \/>\nHigh\/Low alarm (switch selectable)<\/p>\n<p>Alarm indication<br \/>\nAlarm state indicated by yellow LED<\/p>\n<p>Response time<br \/>\napprox. ca. 20 ms<\/p>\n<p>Operation temperature<br \/>\n-20 to +60 \u00b0C \/ -4 to +140 \u00b0F<\/p>\n<p>Galvanic isolation<\/p>\n<p>Input \/ power supply \/ relay outputs<br \/>\n4 kVAC, 1 min<\/p>\n<p>Relay 1 \/ Relay 2<br \/>\n3 kVAC, 1 min<\/p>\n<p>Power supply<\/p>\n<p>Voltage<br \/>\n24 VAC\/DC \u00b115 %, 48 to 62 Hz (AC supply). 24 V CD, \u00b1 15 %, 1.0 W<\/p>\n<p>Typical accuracy<br \/>\nTrip point: \u00b10.2 % of span<\/p>\n<p>Mounting<br \/>\n35 mm DIN rail acc. to EN 60715<\/p>\n<p>[\/vc_column_text][vc_column_text el_id=&#8221;documents&#8221; el_class=&#8221;docs section&#8221;]<br \/>\nDocuments<br \/>\n[wpfd_category id=&#8217;12162&#8217;\/][\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"featured_media":37658,"template":"","meta":[],"product_brand":[],"product_cat":[257],"product_tag":[],"class_list":["post-22992","product","type-product","status-publish","has-post-thumbnail","product_cat-alarm-units","first","instock","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SR361 - INOR<\/title>\n<meta name=\"description\" content=\"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/inor.com\/product\/sr361\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SR361 - INOR\" \/>\n<meta property=\"og:description\" content=\"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/inor.com\/product\/sr361\/\" \/>\n<meta property=\"og:site_name\" content=\"INOR\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-13T09:55:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/inor.com\/wp-content\/uploads\/2024\/02\/sr361_web-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"230\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/\",\"url\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/\",\"name\":\"SR361 - INOR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/krohne-inor.fi\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/krohne-inor.staging.rackfish.net\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/sr361_web-1.webp\",\"datePublished\":\"2024-02-15T08:21:01+00:00\",\"dateModified\":\"2025-03-13T09:55:24+00:00\",\"description\":\"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/#primaryimage\",\"url\":\"https:\\\/\\\/krohne-inor.staging.rackfish.net\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/sr361_web-1.webp\",\"contentUrl\":\"https:\\\/\\\/krohne-inor.staging.rackfish.net\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/sr361_web-1.webp\",\"width\":230,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/inor.com\\\/product\\\/sr361\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Hem\",\"item\":\"https:\\\/\\\/inor.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SR361\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/krohne-inor.fi\\\/#website\",\"url\":\"https:\\\/\\\/krohne-inor.fi\\\/\",\"name\":\"INOR\",\"description\":\"Specialists in industrial temperature measurement\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/krohne-inor.fi\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SR361 - INOR","description":"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/inor.com\/product\/sr361\/","og_locale":"en_US","og_type":"article","og_title":"SR361 - INOR","og_description":"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.","og_url":"https:\/\/inor.com\/product\/sr361\/","og_site_name":"INOR","article_modified_time":"2025-03-13T09:55:24+00:00","og_image":[{"width":230,"height":300,"url":"https:\/\/inor.com\/wp-content\/uploads\/2024\/02\/sr361_web-1.webp","type":"image\/webp"}],"twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/inor.com\/product\/sr361\/","url":"https:\/\/inor.com\/product\/sr361\/","name":"SR361 - INOR","isPartOf":{"@id":"https:\/\/krohne-inor.fi\/#website"},"primaryImageOfPage":{"@id":"https:\/\/inor.com\/product\/sr361\/#primaryimage"},"image":{"@id":"https:\/\/inor.com\/product\/sr361\/#primaryimage"},"thumbnailUrl":"https:\/\/krohne-inor.staging.rackfish.net\/wp-content\/uploads\/2024\/02\/sr361_web-1.webp","datePublished":"2024-02-15T08:21:01+00:00","dateModified":"2025-03-13T09:55:24+00:00","description":"Alarm Unit with Current and Voltage Input and Double Relay Outputs. SR361 is designed for monitoring current and voltage signals in the process industry.","breadcrumb":{"@id":"https:\/\/inor.com\/product\/sr361\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/inor.com\/product\/sr361\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/inor.com\/product\/sr361\/#primaryimage","url":"https:\/\/krohne-inor.staging.rackfish.net\/wp-content\/uploads\/2024\/02\/sr361_web-1.webp","contentUrl":"https:\/\/krohne-inor.staging.rackfish.net\/wp-content\/uploads\/2024\/02\/sr361_web-1.webp","width":230,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/inor.com\/product\/sr361\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Hem","item":"https:\/\/inor.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"\/products\/"},{"@type":"ListItem","position":3,"name":"SR361"}]},{"@type":"WebSite","@id":"https:\/\/krohne-inor.fi\/#website","url":"https:\/\/krohne-inor.fi\/","name":"INOR","description":"Specialists in industrial temperature measurement","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/krohne-inor.fi\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/product\/22992","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/media\/37658"}],"wp:attachment":[{"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/media?parent=22992"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/product_brand?post=22992"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/product_cat?post=22992"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/krohne-inor.staging.rackfish.net\/en\/wp-json\/wp\/v2\/product_tag?post=22992"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}